Microbiology, pesticides, PFAS, heavy metals. Every parameter was analyzed before and after passing through the FLX Compact, by two independent COFRAC-accredited laboratories. Here are the results.

Tests performed by IANESCO (Poitiers) and CAIRAP, COFRAC-accredited, on raw river water, tap water, and agricultural water.
Awarded at the 2024 International Concours Lépine, and subsequently distinguished with the 2025 Groupama Pro Prize.
Designed and assembled in our workshop in the 86 department, in Nouvelle-Aquitaine.
Vincent L. has lived in the Vienne for 23 years, surrounded by fields. Used to bottled water since childhood, he had never drunk his tap water. He shares what changed the day it was installed.
"We were used to drinking bottled water, exclusively. We never drank tap water because it was very heavily loaded with pesticides."
"When the machine was installed, I admit it was like a miracle. I had poured a glass of tap water before, and a glass with the water after."
"Today, we don't buy water anymore; we only consume tap water. It feels like we're really living at home, with our own drinking water."
Machine, filter, and mounting kit delivered upon registration. No commitment, cancel with one click.
Tests performed on raw river water (Marne), non-compliant tropical tap water, and agricultural water. The same result in all three cases.
Click on a parameter family to see the detailed measurements.
| Parameter | Raw water | Treated water | WHO/EU standard | Efficiency |
|---|---|---|---|---|
| Escherichia coliIndicator fecal bacteria | sup. to 80 /100 mL | 0 | 0 /100 mL | >99% |
| Total coliformsContamination indicators | sup. to 80 /100 mL | 0 | 0 /100 mL | >99% |
| Intestinal enterococciFecal indicators | sup. to 80 /100 mL | 0 | 0 /100 mL | >99% |
| Salmonella sppEnteric pathogen | Present | Absent | Absence | >99% |
| Sulfite-reducing anaerobic sporesDeep contamination | Present | Not detected | 0 | >99% |
| Parameter | Raw water | Treated water | Standard | Efficiency |
|---|---|---|---|---|
| TurbidityVisual clarity of water | 43 to 75 NTU | less than 0.94 NTU | ≤ 2 NTU | >99% |
| ColorColored suspended matter | 50 mg/L Pt | 2.5 mg/L Pt | ≤ 15 mg/L | >95% |
| Total organic carbonDissolved organic matter | 4 mg/L | less than 0.3 mg/L | ≤ 2 mg/L | >92% |
| Total aluminumHeavy metal, flocculant | 2,500 µg/L | less than 20 µg/L | ≤ 200 µg/L | >99% |
| Total ironMetal, taste and coloration | 2,100 µg/L | less than 10 µg/L | ≤ 200 µg/L | >99% |
| Total manganeseMetal, black coloration | 40 µg/L | 4 µg/L | ≤ 50 µg/L | 90% |
| Total arsenicToxic metalloid | 1 µg/L | less than 0.2 µg/L | ≤ 10 µg/L | >80% |
| Benzo(a)pyrenePolycyclic aromatic hydrocarbon | 0.011 µg/L | less than 0.0025 µg/L | ≤ 0.01 µg/L | >77% |
| Molecule | Raw water | Treated water | Standard | Efficiency |
|---|---|---|---|---|
| PropyzamideHerbicide, amide family | 0.61 µg/L | less than 0.010 µg/L | ≤ 0.1 µg/L | >98% |
| Chlorothalonil R471811Fungicide metabolite | 0.51 µg/L | less than 0.040 µg/L | ≤ 0.1 µg/L | >92% |
| Metolachlor ESAHerbicide metabolite | 0.11 µg/L | less than 0.020 µg/L | ≤ 0.1 µg/L | >97.9% |
| Metolachlor OXAHerbicide metabolite | 0.063 µg/L | less than 0.020 µg/L | ≤ 0.1 µg/L | >97.9% |
| ChlortoluronHerbicide, urea family | 0.22 µg/L | less than 0.020 µg/L | ≤ 0.1 µg/L | >91% |
| GlyphosateHerbicide, aminophosphonate | 0.033 µg/L | less than 0.030 µg/L | ≤ 0.1 µg/L | >90% |
| ProsulfocarbHerbicide, carbamate | 0.12 µg/L | less than 0.030 µg/L | ≤ 0.1 µg/L | >75% |
| Flufenacet ESAHerbicide metabolite | 0.14 µg/L | less than 0.020 µg/L | ≤ 0.1 µg/L | >86% |
| Molecule | Raw water | Treated water | EU 2026 standard | Efficiency |
|---|---|---|---|---|
| PFHxS, perfluorohexanesulfonic acidLong-chain PFAS | Detected | Not detected | ≤ 0.1 µg/L | >99.8% |
| PFNA, perfluorononanoic acidPFAS, endocrine disruptor | Detected | Not detected | ≤ 0.1 µg/L | >99.8% |
| PFOA, perfluorooctanoic acidPFAS classified as a possible carcinogen | Detected | Not detected | ≤ 0.1 µg/L | >99.7% |
| PFOS, perfluorooctanesulfonic acidPFAS banned but persistent | Detected | Not detected | ≤ 0.1 µg/L | >99.8% |
| TFA, trifluoroacetic acidShort-chain PFAS, highly mobile | Detected | Not detected | ≤ 0.5 µg/L | >91% |
| PFBA, PFBs, PFHxAShort-chain PFAS, Marne river | 0.001 to 0.002 µg/L | Not detected | ≤ 0.1 µg/L | >99% |
€59.99 incl. tax per month, filters included and delivered 3 times a year. No commitment.

Poitiers, France. Reports E23-58155/58156 (Marne river, December 2023) and E25-05453/05454 (agricultural water, February 2025). COFRAC accreditation no. 1-0209, approved by the Ministries of Health and Environment.

Arue, French Polynesia. Reports 2024.4587 (raw water) and 2024.4278 (treated water, October and November 2024). COFRAC accreditation no. 1-1426. Sampling performed by the laboratory.

Analyses performed according to NF EN ISO standards, by laboratories accredited by the French Accreditation Committee (COFRAC). Accreditations available for consultation at cofrac.fr.
The oldest French institution dedicated to invention has distinguished our home filtration technology.
Recognition of the practical utility of the solution for both individuals and professionals.
Materials in contact with water meet NSF requirements and French Sanitary Conformity Certification (ACS).
Our workshop is located in the 86 department, in the Nouvelle-Aquitaine region. This is where FLX Compact units are assembled, checked individually, and then shipped, just a few kilometers from the IANESCO laboratories in Poitiers, which validate our performance.
Assembly and individual quality control in the Vienne.
Machine, filter, and mounting kit, shipped from France.
On the machine, parts included.
A reachable team that knows the product and your installation.
Through two complementary mechanisms. First, hollow fibers calibrated to 0.1 microns, which physically block microplastics, bacteria, and suspended particles. Second, electro-adsorption: nanoparticles in the media capture negatively charged contaminants, including particles as small as 0.001 microns like viruses and PFAS. An activated carbon stage completes the process for pesticides, chlorine, and residues.
On both, intentionally. Tests were conducted on raw river water (the Marne), non-compliant tap water, and agricultural water. In all three cases, the treated water was compliant with the limits of the Public Health Code.
Yes. The IANESCO and CAIRAP reports are available upon request: send us a message via our contact form and we will provide them to you with their sampling numbers and dates.
No, and that is a choice. Unlike a reverse osmosis system, the FLX Compact retains the calcium and magnesium naturally present in the water. It does not treat limescale, either: it is not a water softener.
About 4 months, which is 3 filters per year. With the subscription plan, they are delivered automatically to your home. With a one-time purchase, you order them from your customer area (€120 incl. tax).
No-commitment subscription, cancelable with one click from your customer area.
Machine, filter, and mounting kit delivered within 48 business hours. No commitment, 5-year warranty.